Search in title
Search in content
Search in title
Search in content

Surface Optics SOC 410 VIS IR Emissometer Reflectometer

Dual-Head Emissometer Reflectometer for Testing Solar Reflectance Index

The Surface Optics SOC 410 VIS IR emissometer reflectometer is a dual-head instrument that combines the 410 Solar reflectometer head with the ET-100 thermal emissometer head with one 410-Series command module for the measurement of emissivity and solar reflectance values that are necessary to determine the Solar Reflectance Index of a material in accordance with ASTM E1980.

The 410 Solar sensor head attaches to the 410 command module and provides for measurements of reflectance in accordance with ASTM E903 and C1549, the standard test methods for solar reflectance measurements. The interchangeable ET-100 sensor head provides for measurements of directional reflectance and emissivity in six bands in the thermal infrared spectral region in accordance with ASTM E408 and E1980. Based on those values, the solar reflectance index (SRI) is computed in accordance with ASTM E1980 (Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surface).

Surface Optics SOC 410 VIS IR Emissometer Reflectometer Overview

The Surface Optics SOC 410 VIS IR emissometer reflectometer is a dual-head instrument that combines the 410 Solar reflectometer head with the ET-100 thermal emissometer head with one 410-Series command module for the measurement of emissivity and solar reflectance values that are necessary to determine the Solar Reflectance Index of a material in accordance with ASTM E1980.

The 410 Solar sensor head attaches to the 410 command module and provides for measurements of near-normal reflectance (total hemispheric, diffuse and specular) averaged within 7 wavebands from 330 to 2500nm in accordance with ASTM E903 and C1549, the standard test methods for solar reflectance measurements.

The ET-100 sensor head can be attached to the command module in place of the 410 Solar head for measurements of directional reflectance in six bands in the thermal infrared spectral region (1.5 to 21μm) at two incidence angles, 20° and 60° in accordance with ASTM E408 and E1980. Based on those values, directional and total hemispherical emissivity is calculated.

Combining the results from the 410 SOLAR and the ET-100 measurement heads provides for measurements of reflectance, solar absorptance and thermal emissivity. From this data set, the solar reflectance index (SRI) is computed in accordance with ASTM E1980 (Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surface).

The 410 VIS IR is Part of the Surface Optics 410 Family

The 410 VIS IR forms part of the 410 range of portable reflectometers and emissometers from Surface Optics Corp (SOC) that are designed for reflectance, solar absorbance and thermal emissivity measurements in the visible to far infrared range. These modular devices feature interchangeable measurement heads and a common command module and generate data of comparable quality to much larger laboratory instruments.

Surface Optics SOC 410 Modular Reflectometer Concept

410 Solar Head for Reflectance & Solar Absorptance Measurements

The 410 Solar measurement head provides for measurements of reflectance (total hemispheric, diffuse and specular) averaged within 7 wavebands from 330 to 2500nm. Measurements are made in the following bands: 335-380nm; 400-540nm; 480-600nm; 590-720nm; 700-1100nm; 1000-1700nm; and 1700-2500nm. The 410 Solar employs a tungsten lamp with integrating sphere for measurements in a 20°/H geometry (directional illumination at 20° to surface normal with hemispheric collection). Solar absorptance is calculated for a number of solar irradiance (air mass) functions, including AM0 (extra-terrestrial) and AM1.5 (terrestrial).

The 410 Solar is compliant with ASTM E903 (Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres) and C1549 (Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer). 

ET-100 Head for Total Hemispherical Emissivity Measurements

The ET-100 provides for measurements of reflectance and thermal emissivity in the 1.5-21μm waveband. Measurements of total hemispheric reflectance are made with the ET-100 head at 20° and 60° incidence and averaged within 6 wavebands between 1.5 to 21μm. Measurements are made in the following bands: 1.5-2μm; 2-3μm; 3-4μm;4-5μm; 5-10μm; and 10-21μm. The ET-100 employs a thermal filament source maintained at 1000°C within an integrating sphere. The integration of these values with the Planck function gives the directional thermal emissivity, from which the hemispheric thermal emissivity is computed. The ET-100 is compliant with ASTM E408 (Total Normal Emittance of Surfaces Using Inspection-Meter Techniques).

Emissivity is that property of a material that determines its effectiveness at emitting thermal radiation, defined as the ratio of the quantity of thermal radiation emitted from a surface compared to the perfect black body radiator maintained at the same temperature, given by the Stefan-Boltzmann law. The measurement of emissivity is important for the calibration of pyranometers and thermal cameras which make non-contact temperature measurements.

Calculation of Solar Reflectance Index per ASTM1980

Combining the results from the 410 Solar and the ET-100 measurement heads provides for measurements of reflectance, solar absorptance and thermal emissivity. From this data set, the solar reflectance index (SRI) is computed in accordance with ASTM E1980 (Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surface).

Ergonomic Design

The lightweight pistol-grip design of the 410 VIS IR is modelled on a battery operated power tool. It is highly portable and allows single-handed use. Simply hold the sample port against the surface to be tested and press the trigger to take the measurement. View results immediately on the touch-screen display. Measurements can be taken on curved surfaces without special jigs or fixtures. The 410 VIS IR measures the reflectance and emissivity of flat, convex and concave surfaces (max. 150mm & 300mm radius, respectively) with a measurement spot of 6.4mm or 12.7mm diameter respectively.

An optional bench-top remote control unit (RCU) is available for the 410-VIS-IR and operates by remote external control from a customer-supplied Windows PC. The bench-top configuration is ideal for routine QC applications and for installations where the measurement head is mounted on a robot arm.

Surface Optics SOC 410 VIS IR Emissometer Reflectometer Specifications

Parameter

410 VIS IR Specifications

 

With 410 Solar Measurement Head

Measurement Capabilities

Total reflectance (directional hemispheric reflectance, DHR); total solar reflectance; solar absorptance

Computed Measurements

Specular-only reflectance; solar absorptance for a variety of solar irradiance functions (e.g. AMO extra-terrestrial & AM1.5 terrestrial etc)

Measurement Geometry

Integrating sphere with 20°/H geometry (directional illumination at 20° with hemispheric collection)

Illumination Source

Incandescent lamp

Measurement Range

7 bands in the 330-2500nm range (335-380, 400-540, 480-600, 590-720, 700-1100, 1000-1700 & 1700-2500nm)

Measurement Spot Size

6.4mm diameter

Measurement Time

10 seconds

 

With ET-100 Measurement Head

Measurement Capabilities

Total reflectance (directional hemispheric reflectance, DHR)

Computed Measurements

Directional & hemispheric thermal emissivity

Note that measurements must be made at ambient temperatures. Emissivity can be calculated by ET100 software for various temperatures; user input temperature function

Measurement Geometry

Integrating sphere with 20°/H & 60°/H geometry (directional illumination at 20° or 60° with hemispheric collection)

Illumination Source

1000°C thermal filament source

Measurement Range

6 bands in the 1.5-21μm range (1.5-2; 2-3; 3-4; 4-5; 5-10; & 10-21μm)

Measurement Spot Size

12.7mm diameter

Measurement Time

10 seconds

 

Combining 410 Solar & ET-100 Measurement Data

Computed Measurements

Combining 410 Solar & ET-100 measurement data allows the operator to manually compute solar reflectance index (SRI) in accordance with ASTM E1980

 

General

Sample Types

Flat or curved surfaces; convex and concave surfaces to have a maximum 150 & 300mm radius, respectively

Calibration

410 Solar is supplied with standards of specular and diffuse reflectance; ET-100 is supplied a gold standard of specular reflectance

Compliance

ASTM E903 (Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres)

ASTM C1549 (Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer)

ASTM E408 (Total Normal Emittance of Surfaces Using Inspection-Meter Techniques)

ASTM E1980 (Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surface)

Power

Rechargeable LiMH battery; 2 hours run-time on one battery charge (1 hour recharge time)

Dimensions

293 x 230 x 94mm (command unit with one head)

Weight

2.13kg (command unit with one head)

The Surface Optics SOC 410 VIS IR emissometer reflectometer is supplied with the following accessory items:

Qty

Accessory Description

1

SOC-410 Command Module

1

410 Solar Measurement Head

Provides for measurements of Provides for measurements of DHR (directional hemispheric reflectance) in the 330-1500nm range, and the computation of solar absorptance for a variety of solar spectral irradiance functions (e.g. AM0 + AM1.5)

1

ET-100 Measurement Head

Provides for measurements of DHR (directional hemispheric reflectance) in the 1.5-21m range, and the computation of directional & hemispheric thermal emissivity

1

1 x Diffuse Reflectance & 1 x Specular Reflectance Standards for 410 Solar Head

1

Specular Gold Calibration Standard for ET-100

1

Battery pack

1

Battery charger

Options

Description

SOC-0410-0019

Benchtop Remote Control (220VAC)

SOC-0410-0101

Specular Gold Calibration Standard (NIST Traceable) – for ET-100

SOC-0410-0106

Diffuse Reflectance Calibration Standard (NIST Traceable) – for 410 Solar

SOC-0410-0104

Specular Gold Calibration Standard (NIST Traceable) – for 410 Solar

SOC-0410-0205

SD Card for Additional Data Storage

The Surface Optics SOC 410 VIS IR emissometer reflectometer can be used for:

  • Measurements of DHR (directional hemispheric reflectance, solar absorptance and thermal emissivity
  • Characterisation of cool roof materials and Green Building certification (LEED)
  • Evaluation of mirrors (degradation, fouling) used in solar power generation; CSP, concentrated photo-voltaic
  • Solar reflectance measurement used in Solar Reflectance Index (SRI) for LEED certification; characterising solar reflectance of roofing and construction industry materials
  • Measurements of solar absorptance of aerospace coatings (i.e., satellites, rockets and spacecraft)
  • Evaluation of mirrors used in astronomical applications (observatory telescopes)
  • Surface evaluation of electroplated materials
  • Evaluation of glass; degradation and fouling
  • Quality assurance / quality control of products for reflectivity using total, diffuse & specular readings
  • Reflectance standards & targets (performance verification)

 

The 410 VIS IR complies with the following standards:

  • ASTM E903 (Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres)
  • ASTM C1549 (Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer)
  • ASTM E408 (Total Normal Emittance of Surfaces Using Inspection-Meter Techniques)
  • ASTM E1980 (Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surface)

Thanks for getting in touch!
Our team will respond as soon as possible.

Product Enquiry

Please complete all fields