Introducing the SPREADMASTER by Weneos, a cutting-edge innovation in sun protection evaluation. Tailored for professionals seeking precision, this compact and lightweight device delivers exceptional performance with an accuracy of 0.005 mm (5 μm).
The SPREADMASTER ensures even application of sunscreen on PMMA molded (HD6) and sandblasted (SB6) substrates, guaranteeing reproducibility and precise measurements. Compliant with solar standards like ISO 24443:2021, it is indispensable for accurate SPF and UVA protection assessments. Its compact design is perfect for space-constrained labs, and its portability makes it easy to handle.
This improved version is designed to meet the needs of professionals who demand unrivalled precision in the application of sun care products. Smaller, lighter and equipped with cutting-edge technology, the SPREADMASTER offers enhanced performance that redefines market standards with an accuracy of 0.005 mm (5 μm).
With its ability to spread sunscreen products evenly on substrates PMMA molded (HD6) and sandblasted (SB6)the SPREADMASTER ensures reproducibility and precise measurement of sun protection, facilitating research and development of new, effective products. Fully compliant with solar standards such as ISO 24443:2021, ISO 23675:2024, ISO 23698:2024 and others, making this robot indispensable for the accurate assessment of Sun Protection Factors(SPF), UVA protection(UVAPF), and more.
With its compact design, the SPREADMASTER can be placed on a bench, making it ideal for use in laboratories with restricted space, while its light weight allows easy handling and increased portability.
| Technical Information | Weneos Robot Spreadmaster |
| Overall dimensions | W: 317 mm x D: 687 mm x H: 583 mm (Approx. 4 x smaller than previous HD-SPREADMASTER version) |
| Total weight | 29 kg (4x lighter than previous HD-SPREADMASTER version) |
| Precision | 0.005 mm repeatability on X, Y and Z axes (20x more accurate than previous HD-SPREADMASTER version) |
| Robotic arm | • Six degrees of freedom (6 rotary joints) • Payload of at least 0.5 kg • Vertical force ( z-axis), adjustable by measuring at the center of the plate (with the mechanical finger and fingerstock, without displacement on the x and y axes), of (6.0 ± 0.5) N • Maximum tool speed of 1 m/s |
| Movement | Step 1 Three circular cycles (one circular cycle corresponding to approximately eight circles per linear arrow, with continuous movement of circles at the hemispheric arrows between the four linear arrows covering the entire area) with 90° rotation between each circular cycle. • First cycle (11.0 ± 0.5) s • Second cycle (11.0 ± 0.5) s • Third cycle (11.0 ± 0.5) s Step 2 Three linear cycles (one linear cycle corresponds to approximately thirteen round trips covering the entire zone), with a 90° rotation between each linear cycle. • Fourth cycle (7.5 ± 0.5) s • Fifth cycle (6.0 ± 0.5) s • Sixth cycle (7.5 ± 0.5) s |
| Compliance | • ISO 23675:2024 – SPF in vitro • ISO 23698:2024 – HDRS • ISO 24443:2021 – UVAPF in vitro • FDA monograph 2011 – Broad Spectrum • Boots Star Rating system 2011 – UVA/UVB ratio |
| Security ce sans quadrillage | • Machinery Directive 2006/42/EC, • Design based on the standards ISO 10218-1:2011, IEC 60204-1/A1:2008, ISO 13849-1:2015, ISO 13849-2:2012, ISO 13850:2015, • 2014/30/EU Electromagnetic Compatibility Directive (EMC), • 2011/65/EU Restriction of the use of certain hazardous substances (RoHS), • 2011/35/EU Low-voltage Directive, • EN IEC 61326-1:2021, • EN IEC 61000-3-2 (2019) A1 (2021), EN IEC 61000-3-3 (2013) A1 (2019) A2 (2021), EN IEC 61000- 4-2 (2008), EN IEC 61000-4-3 (2020), EN IEC 61000-4-4 (2012), EN IEC 61000-4-5 (2014) A1 (2017), EN IEC 61000-4-6 (2013), IEC 61000-4-8 (2009). |
| Power | 90-264 VAC / 50-60 Hz |
| IP class | IP40 |
| Conditions of use | • Temperature : [5°C – 45°C] • Humidity: [10% – 80%] non-condensing |