SBIR Laser Range Test Module

Integrated Test Systems for Laser Rangefinders & Receivers

The Laser Ranging Test Module from Santa Barbara Infrared, Inc. provides the capability to perform range accuracy and receiver sensitivity tests, among others, on laser rangefinders and laser receivers. It uses up to three different laser diodes (1064nm, 1540nm and 1570nm) and a fiber network to provide accurate and dynamic high precision pulsed laser output. At the core is a calibrated detector and electrically variable attenuators to accurately set pulse power, along with a sophisticated timing circuit that dynamically simulates ranges from 50 meters to 60,000 meters. 

The LRTM has a reference flat mirror that can be used to align the LRTM to a UUT through autocollimation. Infrared and Visible targets are provided to properly aim a UUT at the Laser Range Finder. 

The LRTM can be used in three different modes. In the first mode, the LRTM operates as a continuously pulsed laser source to test receivers. In this mode, the wavelength, pulse rate and pulse power can be set by the user. The LRTM can also be used as an electrically triggered pulsed laser source to test Laser Spot Trackers. In the electrically triggered mode the LRTM provides a laser pulse for every trigger pulse. The wavelength and pulse power are set by the user. The LRTM can also be optically triggered, returning single or double laser pulses to test laser range finder accuracy. The user sets wavelength, pulse power, range for first and if required second pulse. The second pulse power and range can be controlled to provide accurate ranging in an obstructed environment. 

Key Features of SBIR Laser Range Test Module

  • 1064 nm, 1540 nm and 1570 nm laser sources
  • Continuous pulsed mode
  • Electronically triggered mode
  • Optically triggered mode
  • First/Last pulse control
  • Easy alignment to UUT

Specifications of SBIR Laser Range Test Module

Wavelength

1,064nm, 1,540nm, 1,570nm

Bandwidth

≤ 10nm Full-Width Half-Maximum

Maximum Pulse Power

≥1,000 nW (1 µW)

Power Dynamic Range

>40 dB

Power Amplitude Accuracy

+/-10%

Pulse Width

20 ns +/- 10 ns

2nd Pulse Ratio Accuracy

+/-10% of set value

Simulated Range

50 to 60,000 meters

Simulated Range Accuracy

+/-1.5 meters or 0.01% whichever is greater

2nd Pulse Delay Range (with respect to the

first pulse programmed delay)

+/-10 to +/-2,000nsec

Optical Trigger Sensitivity

Will trigger with input pulses of ≥ 150kW

Pulse Period Range (in Free Run Mode)

50 msec to 1 sec (20Hz to 1Hz)

Pulse Period Accuracy (in Free Run Mode)

<+/-100nsec

LRTM Beam Divergence

2.5 mrad

Maximum Input Fluence

1.25J/cm2 @ 1064nm 30nsec pulse width

Alignment Gimbal Travel

>+/- 2mrad

Alignment Gimbal Step Resolution

< 65µrad

Laser Beam Output Alignment to Reference Flat mirror  

< 100µrad